What was found
DOOR 1 WET AREA ,LONGERON AT Y-1959 BETWEEN FR12 AND FR18 FOUND TO HAVE SUSPECT CORROSION AT FR16A AS MARKED. CORROSION REMOVAL CARRIED OUT IAW SRM 51-22-00 REV 91. BLEND DIMENSIONS; L=1.5", W=0.75", D=0.060". BLEND AREA FOUND BEYOND LIMITS OF SRM 51-11-15 REV 91. CORROSION RII C/O FOR LVL 2 CORROSION IAW GMM VOL1 CHAPTER 5 1.8.2 REV 43. LONGERON REPLACED IAW DWG F53113473 AND SRM 51-72-11 REV 91. JOB C/P.