What was found
DOOR 1 WET AREA , SEAT TRACK Y-953 BETWEEN FR 11 TO FR 18 AT FR 13A ,HAS AN AREA OF SUSPECT CORROSION ON RUN OUT AREA AS MARKED. CORROSION REMOVED IAW SRM 51-22-00 R91. BLEND OUT DIMENSIONS L=3.0", W=1.75", D=0.065" FOUND TO BE OUT OF LIMITS IAW A330 SRM 53-11-15 R91. CORROSION RII C/O FOR LVL 2 CORROSION IAW GMM VOL1 CHAPTER 5 1.8.2 REV 43. SEAT TRACK REPLACED IAW SRM 51-72-11 REV 91 AND DWG F53114437000 AND F53122518000. JOB COMPLETE