What was found
SCRIBE AND CORROSION DAMAGE FOUND ON AUX FLOOR SUPPORT STRUCTURE AT BS 380, 15 INCHES AFT OF FRAME 75. CORROSION DAMAGE BLENDED IAW SRM 51-74-00 RBL 91. BLEND DIMENSIONS 5.70" X 0.5" DEPTH 0.019". ASSESSED AS OUTSIDE OF SRM 53-00-14 REV 91 LIMITS. REPLACEMENT CARRIED OUT ON IAW SRM 51-72-11 REV 91.