What was found
NR 1 A/C PACK REGULATOR FAULT, NR 1 A/C PACK RAM DOOR CLOSED ECAM DISPLAYED DURING DESCENT. RESET AEVC AND PACK CONT 1 RESET SWITCH, SYSTEM TEST ECS,TESTED OK. IAW AMM 21-26-00-710-803. OPS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 A/C PACK REGULATOR FAULT, NR 1 A/C PACK RAM DOOR CLOSED ECAM DISPLAYED DURING DESCENT. RESET AEVC AND PACK CONT 1 RESET SWITCH, SYSTEM TEST ECS,TESTED OK. IAW AMM 21-26-00-710-803. OPS NORMAL.