Service difficulty report · Bleed Valve · Airbus A330243

Difficulty date
October 14, 2017
Submitted
October 16, 2017
Operation
Air carrier
Aircraft
N393HA
Make and model
Airbus A330243
Aircraft serial
1422
Aircraft time
19,545 hours, 3,140 cycles
Part
Bleed Valve
Condition
Faulted
Location
Nr 1 Engine
Part time
3,140 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 1 ENGINE BLEED FAULT DURING CLIMB. RESET IAW MOC, OPS NORMAL. TROUBLESHOT IAW TSM 36-11-81-810-909-A. REMOVED AND REPLACED THE NR 1 ENGINE BLEED VALVE IAW AMM 36-11-52. OPS CHECKED OK. NO FAULTS NOTED. BITE CHECKED BMC, OK. LEAK CHECKED OK. NO LEAKS. OK FOR SERVICE.