Service difficulty report · Regulator Valve · Airbus A330243

Difficulty date
October 23, 2017
Submitted
October 24, 2017
Operation
Air carrier
Aircraft
N381HA
Make and model
Airbus A330243
Aircraft serial
1114
Aircraft time
33,299 hours, 5,449 cycles
Part
Regulator Valve
Part number
33361190002
Part serial
01965
Condition
Inoperative
Location
Bleed Air Sys
Part time
33,299 hours, 5,449 cycles
Stage of operation
UK
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIR ENGINE NR 1 BLEED FAULT. PERFORMED BITE TEST OF BMC. FAULTED NR 1 PRESSURE REG VALVE, REMOVED AND REPLACED NR 1 PRESSURE REG VALVE PER AMM 36-11-52. LEAK CHECK AND BITE TEST GOOD. OK FOR SERVICE. VALVE, BLEED, P OFF 33-3611-9-0002 01965 ON 33-3611-9-0002 02595.