What was found
ETOPS SIGNIFICANT SYSTEM - L1 MAIN FUEL PUMP INTERMITTENT OPERATION BEGINNING IN DECENT. PERFORMED OPS CK L1 MAIN FUEL PUMP PER AMM 28-21-00-710 PUMP OPS CK GOOD AND VERIFIED. NTF A/C OK FOR SVC.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYSTEM - L1 MAIN FUEL PUMP INTERMITTENT OPERATION BEGINNING IN DECENT. PERFORMED OPS CK L1 MAIN FUEL PUMP PER AMM 28-21-00-710 PUMP OPS CK GOOD AND VERIFIED. NTF A/C OK FOR SVC.