What was found
DIVERSION TO NEAREST AIRPORT DUE TO G HYD FAILURE, LANDED BELOW 400K WEIGHT. FOUND GREEN HYD SYS HP MANIFOLD 5102JM OUTBOARD BLEEDER PLUG ORING DAMAGED. REMOVED AND REPLACED ORING PER AMM 29-11-53, RE-SERVICED GREEN SYSTEM, RAN ALL ELEC AND ENGINE DRIVEN PUMPS, CHECKED ALL ACCUMULATORS, NO LEAKS NOTED, RESET FREE-FALL SYS, MC ADVISED, NO STATUS MSG PRESENT.