Service difficulty report · Pump · Airbus A330243

Difficulty date
September 8, 2018
Submitted
September 20, 2018
Operation
Air carrier
Aircraft
N390HA
Make and model
Airbus A330243
Aircraft serial
1389
Aircraft time
24,932 hours, 3,975 cycles
Part
Pump
Part number
33291290002
Part serial
40265
Condition
Leaking
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HYD G RSVER LOW AIR PRESSURE, FOLLOWED BY A TOTAL LOSS OF G HYD SYSTEM, DIVERTED, ON ARRIVAL , INBOUND CREW STATED THAT NO G HYD QTY, HYD FLUID WAS COMING OUT FROM NR 2 ENG DRAIN MAST , NR 1 HYD PUMP. PRESSURIZED GREEN HYD RESERVOIR IAW AMM 29-14-00-614-804-A01. UNABLE TO PRESSURIZE G RESERVOIR. FOUND AIR LEAK FROM GREEN RESERVOIR. PRESSURIZATION CHECK VALVE DRAIN. REMOVED CHECK VALVE IAW AMM 29-14-31-000-801-A. FOUND CHECK VALVE PARTIALLY STUCK OPEN. REMOVED GREEN ENG HYDRAULIC PUMP IAW AMM 29-11-51. INSTALLED NEW CHECK VALVE ON GREEN RESERVOIR IAW AMM29-14-31. INSTALLED NEW EDP IAW AMM 29-11-51. REPLACED CASE DRAIN FILTER ASSY ON GREEN SYS, NR 1 ENG IAW AMM 29-11-43. PERFORMED LEAK TEST AND NO LEAK NOTED. PERFORMED BLEEDING HYD SYS AND RESET CIRCUIT BREAKER 5JR . ENGINE RUNS PERFORMED , ALL OK, ACFT OK FOR SERVICE.