As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DOOR 1R FLOOR SUPPORT STRUCTURE FWD LWR SUPPORT ANGLE @ FR13A Y-2061 IS CORRODED WHERE INDICATED. CORROSION DAMAGE DIMENSIONS: L=0.300" W=0.500" DEPTH=0.020". DEPTH GAUGE USED P/N: 2417 S/N: IRFE5005A9EQ. UNABLE TO FIND SRM LIMITS FOR THIS COMPONENT. RII CARRIED OUT AS PER GMM VOL 1 CHAP 5 - CONSIDERED LEVEL 2 DAMAGE, PART REPLACEMENT REQUIRED. FLOOR SUPPORT WEB REPLACED AS PER SRM 51-42-11 REV 98.01 AND DRAWING F53113798 ISS B. JOB COMPLETE.