As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS SIGNIFICANT SYSTEM - AFTER STARTING NR 2 ENG ECAM ENG2 OVSP PROT FAULT, ENGINE PARAMETERS NORMAL. MAINT CONTROL TOLD US TO SHUT DOWN ENG 2 AND RESTART. AFTER RESTART NO ECAM OR FURTHER MESSAGE ALL INDICATIONS NORMAL. SYSTEM TEST OF EEC 2 OK NO FAULTS NOTED A/C OK FOR SVC.