What was found
ETOPS SIGNIFICANT SYSTEM - APU GEN FAULT. // PERFORMED TSM 24-20-81-810-942-A. REMOVED AND REPLACED APU GEN PER AMM 24-23-51. OPS NORMAL, NO DEFECTS NOTED. LEAK CHECK OK. OK FOR SVC.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYSTEM - APU GEN FAULT. // PERFORMED TSM 24-20-81-810-942-A. REMOVED AND REPLACED APU GEN PER AMM 24-23-51. OPS NORMAL, NO DEFECTS NOTED. LEAK CHECK OK. OK FOR SVC.