What was found
ETOPS / DURING CLIMB ENG 2 FIRE LOOP FAULT ILLUMINATED, WENT OUT AFTER 1 MINUTE. REMOVED AND REPLACED #2 ENGINE PYLON FIRE DETECTORS (3WD2) AND (4WD2) PER AMM 26-12-16.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS / DURING CLIMB ENG 2 FIRE LOOP FAULT ILLUMINATED, WENT OUT AFTER 1 MINUTE. REMOVED AND REPLACED #2 ENGINE PYLON FIRE DETECTORS (3WD2) AND (4WD2) PER AMM 26-12-16.