What was found
ATB, STRONG FUMES IN ENTIRE AIRCRAFT DURING INITIAL CLIMB FOR UP TO 20 MINS. CLEARED WITH NO USAGE OF CHECKLIST. T/S PER A330 FIM 21-00-00-810-801-A. NO DEFECTS NOTED. INSPECTED BOTH ENG'S . NO DEFECTS . OPENED AND INSPECTED BOTH PACKS AND NO DEFECTS. RAN ENG'S TO POWER PER A330 71-00. PERFORMED PACK DUCT BURNOUT PER A330 AMM 21-00. ALL OPS NML. C/W NO GO ODI PREVENTION. OK FOR SVC.