Service difficulty report · Wire · Airbus A330243

Difficulty date
November 20, 2019
Submitted
November 21, 2019
Operation
Air carrier
Aircraft
N378HA
Make and model
Airbus A330243
Aircraft serial
1615
Aircraft time
19,657 hours, 3,207 cycles
Part
Wire
Condition
Chafed
Location
Nr 2 Generator
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ATB - 1 HOUR INTO FLIGHT, #2 ENGINE GENERATOR OFF. RAN ECAM CHECKLIST, RETURNED TO DEPARTED STATION. // ACCOMPLISHED TSM 24-20-81-810-854-A UO TO STEP E (2), BITE TEST GIVES MESSAGE TEST OK. NEED TO CONTINUE RESISTANCE CHECK. ACCOMPLISHED TSM 24-20-81-810-854-A, UP TO STEP 4F (2)(A), NO FAULTS FOUND, CONTINUE TSM 24-20-81-810-854-A TO STEP 4F(2)(B) 2,B INSULATION CHECK OK. INSPECTION OF IDG WIRE HARNESS ON #2 FOUND CHAFED WIRES FOR EXC FILED (IE003R16/B16) AND PMG (1E002R16/Y16), REPLACED WIRES IE003R16/B16FOR FILED AND WIRES 1E002R16/Y16 FOR PMG PER AMM 70-71-24, #2 ENG IDG AND WIRES, OPS CHECK PENDING. OPS CHECK GOOD. CONDITION OF CONNECTORS CHECK OK. OK FOR SERVICE.