What was found
NR 1 ENGINE FIRE LOOP -A- FAULTED ECAM DURING APPROACH. TROUBLESHOT IAW TAM 26-12-00-810-851-A, POST SB 26-1112. DETECTOR CONFIRMED AND NO FAULTS NOTED ON OPERATIONAL TEST, VISUAL INSPECTION OF DETECTORS AND HARNESS FOUND NO DEFECTS NOTED, RESTIANCE CHECK AT DETCTOR 4001WD1 WITHING LIMITS. OK TO CONTINUE.