What was found
ETOPS SIGNIFICANT SYSTEM - BTB - ECAM: ENG 2 FADEC SYS FAULT FOLLOWED BY ENG 2 MINOR FAULT OIL CHIP DETECTED. // INSTALLED NEW PHMU ON #2 ENG, CONDITION SAME. RE-INSTALLED ORIGINAL PHMU PER AMM 77-31-01. REMOVED AND REPLACED #2 EEC PER AMM 73-21-01. LAND TEST PASSED PER 22-97-00. CHECKED #2 CHIP DETECTORS, NO METAL FOUND. RAN #2 ENG, NO FAULTS, OK FOR SVC.