What was found
LHW MLG: LH WING MLG RIB 6 FWD LUG BORE CORROSION BEYOND WORK CARD #5753-01164-08A, FIGURE 1(SHEET 20F4). TO CARRY OUT CORROSION REMOVAL. // CARRIED OUT CORROSION REMOVAL ON FWD LUG BORE IN ACCORDANCE TO STEPS INSTRUCTED IN ER/A #586358-14 REV 0. FINAL DIMENSION RECORDED IN PRI 586358-14 REV 0, APPENDIX A. OVERSIZE BUSHES ON FWD AND AFT LUG FABRICATED IN ACCORDANCE TO APPENDIX 2 AN PART MARK PER PMS 01-06-12. OVERSIZE BUSHES ON FWD AND AFT LUG INSTALLED IN ACCORDANCE TO PRI 586358-14 REV.0 STEPS. FINAL DIMENSION G AND H MEASURED WITHIN LIMIT FWD AND AFT LUG BUSHES INTERNAL DIAMETER HONED TO LIMIT PER PRI 586358-14 REV.0 ASSOCIATED ER/A 14-586358 ADDED FOR AC 0380