What was found
Z670 RHW:RH WING MLG RIB 6 FWD LUG BORE CORROSION BEYOND WORK CARD #5753-01164-08B, FIGURE 1(FIGURE 02 OF 04). TO CARRY OUT CORROSION REMOVAL. // CARRIED OUT CORROSION REMOVAL ON FWD LUG BORE IN ACCORDANCE TO STEPS INSTRUCTED IN ER/A 586359-14 REV 0 FINAL DIMENSION RECORDED IN PR 1586359.14 REV 0. APPENDIX A. OVERSIZE BASHES ON FWD AND AFT LUG FABRICATED IN ACCORDANCE TO APPENDIX 2 OF PR 1586359.14 REV 0, NEW PART NUMBER PART MARK PER PMS01-06-12. OVERSIZED BUSHED ON FWD AND AFT LUG INSTALLED IN ACCORDANCE TO PR1586359.14 REV 0 STEPS. FINAL DIMENSION G AND H MEASURED WITHIN LIMIT FWD AND AFT LUG INSTALLED IN ACCORDANCE TO PR1586359.14 REV 0 STEPS. FINAL DIMENSION G AND H MEASURED WITHIN LIMIT, FWD AND AFT LUG BUSHES INTERNAL DIAMETER HONED TO LIMIT PER PR1586359.14 REV 0.