Service difficulty report · Actuator Valve · Airbus A330243

Difficulty date
April 16, 2020
Submitted
April 17, 2020
Operation
Air carrier
Aircraft
N386HA
Make and model
Airbus A330243
Aircraft serial
1302
Aircraft time
37,031 hours, 5,624 cycles
Part
Actuator Valve
Part number
43282690002
Part serial
53837
Condition
Faulty
Location
Fuel System
Part time
4,986 hours, 762 cycles
Stage of operation
TX
How discovered
O
Nature of condition
O
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ETOPS SIGNIFICANT SYSTEM - FUEL AFT TRANSFER INOP ECAM AFTER 2ND ENG START RESET BOTH FCMC AND FWC BTB.// REMOVED AND REPLACED OUTER TANK FUEL INLET VALVE ACTUATOR 500QU1 PER 28-25-57 OPS CHECK OK OK FOR SVC.