What was found
ETOPS SIGNIFICANT SYSTEM - NR 2 ENG HYD EDP LEAKING (GREEN). REMOVED AND INSTALLED NR 2 ENG HYD EDP (GREEN) PER AMM 29-11-51-400-810-A. LEAK CHECK OK. OK TO CONTINUE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYSTEM - NR 2 ENG HYD EDP LEAKING (GREEN). REMOVED AND INSTALLED NR 2 ENG HYD EDP (GREEN) PER AMM 29-11-51-400-810-A. LEAK CHECK OK. OK TO CONTINUE.