What was found
ENG NR 2 VIB INDICATORS AMBER (X) LOG-PAGE UPDATED AT 18SEP20 2344 UTC. WHILE PERFORMING TSM 73-25-81-810-916-A, REMOVED AND REPLACED NR 2 ENGINE REMOTE CHARGE CONVERTER, PER AMM 77-32-13--400-802-A. OPS CHECK OF INDICATION FAILED. REQUIRES FURTHER TROUBLESHOOTING AS 1649860 9/18/20. REINSTALLED ORIGINAL RCC, PER AMM 77-32-13. REMOVED AND REPLACED NR 2 EIVMU, PER AMM 73-25-34. NR 2 ENG VIB INDICATION NORMAL, OK FOR SVC. UNIT, ENGINE, I OFF 43-7325-9-0001 04578 ON 43-7325-9-0001 04272 LOG-PAGE UPDATED AT 18SEP20 2344 UTC.