What was found
492 C CHECK. SM S/C AROUND STA 974 AND LONG 30 (M). REMOVED CORROSION, PER B717SRM 51-10-04-OG-O. FOUND TO BE BEYOND LIMITS, PER SRM 53-00-090-1A 0 FIG 103 M66 SUBMITTED. PENDING INSTALLATION OF FASTENERS TREAT PRIME AND PAINT POST REPAIR. INSTALLED LOCK FASTENERS, PER B717SRM 51-41-05-OG-O. INSTALLED RIVETS, PER B717SRM 51-41-02-OG-O. TREATED PRIMED AND PAINTED AREA, PER B717 SRM 51-22-01-OG-O. BLEND OF FRAME AT STA 974 LONGERON DUE TO CORROSION (E105-492092-PERM).