What was found
ETOPS, AFTER LANDING ECAM MESSAGE "ENGINE 2 CONTROL SYSTEM FAULT" LOG-PAGE UPDATED AT 18NOV20 0401 UTC. TROUBLESHOT, PER TSM 75-33-00-810-810-808-A. RECEIVED "TEST INCOMPLETE" DURING MCDY VSV TEST. 16 NOV 20 1533630. REMOVED AND REPLACED NR 2 ENGINE VSV CONTROLLER, PER AMM 75-33-51-400-801A TO STEP 4 (D). 152694. PERFORMED LEAK CHECK OF NR 2 ENGINE VIGV/VSV CONTROL UNIT, PER AMM 75-33-51. TEST OK. CONTROL, VARIAB OFF 43-7533-9-0001 10374 ON 43-7533-9-0001 10387.