Service difficulty report · Control Unit · Airbus A330243

Difficulty date
October 2, 2020
Submitted
December 3, 2020
Operation
Air carrier
Aircraft
N383HA
Make and model
Airbus A330243
Aircraft serial
1217
Aircraft time
42,503 hours, 6,673 cycles
Part
Control Unit
Condition
Faulted
Location
Doors
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EMERGENCY EQUIPMENT-SHIP 383 ECAM MAINTENANCE STATUS DOORS WITH CLASS 2 FAULT MESSAGE PSCU (5MJ). CORRECTIVE ACTION: REMOVED AND REPLACED PSCU (5MJ), PER A330 AMM 52-71. PERFORMED PSCU BITE TEST. FOUND STATIC HOSE CONNECTED TO AMBIENT PORT OF CABIN PRESSURE SWITCH (40MJ). CONNECTED STATIC HOSE TO STATIC PORT OF SWITCH, PER A330 AMM 52-71. OPERATIONS TEST OF CABIN PRESSURE SWITCH GOOD, PER A330 AMM 52-71. PRESSURE LINE LEAK CHECK GOOD, PER A330 AMM 34-22. PSCU BITE TEST PASSED.