Service difficulty report · Pressure Valve · Airbus A330243

Difficulty date
January 4, 2021
Submitted
January 5, 2021
Operation
Air carrier
Aircraft
N391HA
Make and model
Airbus A330243
Aircraft serial
1399
Aircraft time
32,602 hours, 5,114 cycles
Part
Pressure Valve
Part number
43361190002
Part serial
02642
Condition
Defective
Location
Nr 2 Eng Bleed
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ETOPS - DUE TO REPEAT AIR ENGINE 2 BLEED NOT CLOSED ECAM MESSAGE. REMOVED AND REPLACED NR 2 ENGINE PRV, PER AMM 36-11-52-400-804-A, IPC 36-11-52-01. OFF P/N: 43-3611-9-0002 S/N:02642 ON P/N:43-3611-9-0002 S/N:02376. LEAK CHECK GOOD. NO DEFECTS NOTED. OK FOR SERVICE.