As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS - LINE SERVICE REPORTED UNABLE TO PUMP FUEL // FCMC FAULTING L OUTER TANK INLET VALVE FAILED OPEN. (500QU1). REMOVED AND REPLACED L OUTER TANK FUEL INLET VALVE ACTUATOR PER AMM 28-25-57. OPS AND SECURITY CHECK GOOD. NO FAULTS NOTED. OK FOR SVC. ACTUATOR, SINGL OFF 43-2826-9-0001 S/N 85834 ON 43-2826-9-0001 S/N 46123