As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS - FUELER REPORTED END LIGHT FLASHING UNABLE TO REFUEL // GROUND SCAN SHOWS LH INLET INTR TANK ACTUATOR (603QL1) REMOVED AND REPLACED FUEL INLET VALVE (603QL1) ACTUATOR PER AMM 28-26-53. OPS AND LEAK CHK GOOD. OK FOR SVC. ACTUATOR, SINGL OFF 43-2826-9-0001 S/N 68336 ON 43-2826-9-0001 S/N 58212