What was found
C CHECK MAJOR REPAIR - DURING ROUTINE MAINTENANCE TASKS, A CRACK IN THE FUSELAGE AT STATION 1022 AT LONGERON L-14L, AND WAS FOUND ON BOTH THE SKIN (PN 5936436-101) AND ON THE FINGER DOUBLER (PN 5936436-39) BELOW. A 3.8 INCH X 1.1 INCH SECTION WAS CUT OUT OF THE SKIN AND A 3.5 INCHES X 0.5" // REPAIRED PER E105-494063-PERM