What was found
ETOPS - DURING PRE-DEPARTURE WALK AROUND FOUND #2 ENG AOHE LEAKING OIL, RAN ENG AND CONFIRMED OIL LEAKAGE.// REMOVED AND INSTALLED NEW AOHE ON #2 ENG PER AMM 79-21-51. 471318. FUEL AND OIL LEAK TEST PENDING. OPS AND LEAK CHK OK PER AMM 79-21-51. OK FOR SVC. COOLER, OIL-AIR OFF 43-7921-9-0001 S/N 41153 ON 43-7921-9-0001 S/N 41650