What was found
AFTER LANDING #1 ENG SHOWED EGT OVERHEAT (PEGGED RED), IMMEDIATELY SHUT DOWN ENGINE, ALSO SHOWING ENG 1 MINOR FAULT. (REPEAT) // PERFORMED TSM 77-21-00-810-849-A. DURING INSPECTION OF EGT WIRING HARNESS, FOUND A LOOSE CONNECTION ON TERMINAL BLOCK 3019VC ALUMEL (GREEN). TIGHTENED NUT AND SECURED CONNECTION. PERFORMED ENGINE #1 RUN PER AMM 71-00-00-860-810-A, NO DEFECTS NOTED. SYSTEM BITE TEST OF EEC #1 CH.A & CH.B, TEST OK. NO FAULTS NOTED. PER AMM 73-21-00-710-812-A. OK FOR SERVICE.