What was found
ETOPS- DURING CLIMB OUT, ECAM MESSAGE DOOR AVIONIC, INITIALLY NO ABNORMAL CABIN CLIMB V/S BUT WAS FLUCTUATING AFTER A FEW MINUTES. FOUND POSITION OF AVIONICS DOOR HANDLE AJAR AND SPRING TENSIONS LOOSE. REPLACED BOTH AVIONICS DOOR SPRINGS AND PERFORMED OPS TEST OF DOOR WARNING SYSTEM PER AMM 52-71-00-710-801-A. OPS OKAY, SECURITY CHECK OF DOOR OKAY, OK FOR SERVICE