What was found
ETOPS - DURING DESCENT ECAM AIR ENG 1 BLEED HI TEMP DISPLAYED, FOLLOWED PROCEDURE PACK FLOW SET TO LOW, REPEAT WRITE UP. REMOVED AND REPLACED HP BLEED VALVE PER AMM 36-11-51-400-804-A AS PRECAUTIONARY. REF TSM 36-11-00-810-B64-A. FOUND LOOSE BACK SHELL ON CANNON PLUG TO BLEED VALVE. REPLACED BACKSHELL PER RR TRENT700 CMM 70-00-20. OPS AND LEAK CHECKS GOOD, OK FOR SVC. BLEED VALVE PN/SN OFF 6763D090000 / 02998, PN/SN ON 6763D090000 / 03100.