As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS - ON CLIMBOUT #1 ENG BLEED FAULT ECAM: PERFORMED REST - OPS NORMAL. REMOVED AND REPLACED #1 ENG BLEED VALVE PER AMM 36-11-52. PERFORMED LEAK TEST OF BLEED VALVE (4001HA) PER AMM 36-11-52. NO LEAK NOTED. NO FAULT NOTED. OK FOR SERVICE.