What was found
ETOPS-DURING CRUISE LT FUEL TANK TEMP FLUCTUATED BETWEEN -10 DRGREES C TO 49 DEGREES C. REMOVED AND REPLACED FQIC AT 3QT IAW AMM 28-42-34-000-001-A AND 28-42-34-400-001-A. OPS CK GOOD. NO FAULTS. OK TO CONTINUE SVC.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS-DURING CRUISE LT FUEL TANK TEMP FLUCTUATED BETWEEN -10 DRGREES C TO 49 DEGREES C. REMOVED AND REPLACED FQIC AT 3QT IAW AMM 28-42-34-000-001-A AND 28-42-34-400-001-A. OPS CK GOOD. NO FAULTS. OK TO CONTINUE SVC.