What was found
SUPPLEMENTAL TO HALA2023031400041 - DMI# 206653 AIR BLEED MAINTENANCE MESSAGE. (CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY). RESET FWC # 1 & 2 AND BMC # 1 & # 2. PERFORMED TEST OF THE EBAS PER TSM 36-00-00-810-804-A. TEST OK. NO FAULTS DETECTED. AIR BLEED MESSAGE CLEARED ON ECAM. A/C OK TO CONTINUE PLACARD REMOVED. MIC SHEET UPDATED.