What was found
ETOPS - DUIRNG T/C 321-72-HWI-03 LEAK CHECK FOUND PRV MUSCLE TUBE CRACKED AND LEAKING BLEED AIR. REMOVED AND REPLACED PRV MUSCLE TUBE IAW AMM 36-11-52-000-802-A. AND 36-11-52-400-802-A. OPS CK GOOD. LEAK TEST GOOD. OK TO CONTINUE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - DUIRNG T/C 321-72-HWI-03 LEAK CHECK FOUND PRV MUSCLE TUBE CRACKED AND LEAKING BLEED AIR. REMOVED AND REPLACED PRV MUSCLE TUBE IAW AMM 36-11-52-000-802-A. AND 36-11-52-400-802-A. OPS CK GOOD. LEAK TEST GOOD. OK TO CONTINUE.