What was found
ATB - ELEC IDG 2 OIL L PR. ATB ( AC MAIN GEN IDG, GCU, LINE CONTACTOR ( EXCEPT FOR ETOPS BEYOND 180 MINUTES ONE MAY BE INOPERATIVE PROVIDED: APU GEN OPERATES NORMALLY & USED IN FLT / ENSURE APU OIL QTY IS ADEQUATE FOR INTENDED FLT / REVIEW MEL "REMARKS") REMOVED # 2 IDG PER AMM 24-21-51-00-804-A. INSTALLED # 2 IDG PER AMM 24-21-51. OPS AND LEAK CHECK GOOD. OK FOR SERVICE REMOVED PLACARD AND UPDATED MIC SHEET.