What was found
ETOPS - AFTER ENGINE START ECAM AIR PACK 2 OVHT. CREW NOTIFIED MX THAT PACK DISCHARGE TEMP REACHED ABOVE 260°C PER TSM 21-52-00-810-842-A. REPLACED TEMP SENSOR 522HH6 PER AMM 21-53-11. OPS GOOD A/C OK FOR SVC.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - AFTER ENGINE START ECAM AIR PACK 2 OVHT. CREW NOTIFIED MX THAT PACK DISCHARGE TEMP REACHED ABOVE 260°C PER TSM 21-52-00-810-842-A. REPLACED TEMP SENSOR 522HH6 PER AMM 21-53-11. OPS GOOD A/C OK FOR SVC.