What was found
ETOPS - AFTER T/O ENG-2 FIRE LOOP A FAULT MSG, AFTER 2-3 MIN MSG CLEARED ON ITS OWN. REPLACED ENG 2 FIRE LOOP A WIRES 1Z002R20 + 1Z002B20 PER AMM 70-71-26. PERFORMED BITE TEST OF FDU 2 PER AMM 26-12-00-740-804-A. TEST OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - AFTER T/O ENG-2 FIRE LOOP A FAULT MSG, AFTER 2-3 MIN MSG CLEARED ON ITS OWN. REPLACED ENG 2 FIRE LOOP A WIRES 1Z002R20 + 1Z002B20 PER AMM 70-71-26. PERFORMED BITE TEST OF FDU 2 PER AMM 26-12-00-740-804-A. TEST OK.