What was found
ETOPS - ENG 1 HP FUEL VALVE HP FUEL VALVE NOT CLOSED ECAM AFTER ENG SHUTDOWN. REMOVED AND REPLACE ENG 1 FUEL METERING UNIT PER A330 AMM 73-21-52 OPS AND LEAK CHECKS GOOD A/C OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - ENG 1 HP FUEL VALVE HP FUEL VALVE NOT CLOSED ECAM AFTER ENG SHUTDOWN. REMOVED AND REPLACE ENG 1 FUEL METERING UNIT PER A330 AMM 73-21-52 OPS AND LEAK CHECKS GOOD A/C OK FOR SERVICE.