What was found
UPDATED WITH RESOLUTION. ATB - ATB: ELEC GEN 1 FAULT ECAM COULD NOT RESET. REMOVED & REPLACED ENG1 IDG PER AMM 24-21-51, LEAK CHECK GOOD, OPS CHECK GOOD, OK FOR SVC, MIC SHEET CLEARED PLACARD REMOVED
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPDATED WITH RESOLUTION. ATB - ATB: ELEC GEN 1 FAULT ECAM COULD NOT RESET. REMOVED & REPLACED ENG1 IDG PER AMM 24-21-51, LEAK CHECK GOOD, OPS CHECK GOOD, OK FOR SVC, MIC SHEET CLEARED PLACARD REMOVED