Service difficulty report · Smoke Detector · Airbus A330243

Difficulty date
September 5, 2024
Submitted
September 6, 2024
Operation
Air carrier
Aircraft
N395HA
Make and model
Airbus A330243
Aircraft serial
1469
Aircraft time
42,124 hours, 6,569 cycles
Part
Smoke Detector
Condition
Inoperative
Location
Zone 200
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INFO TO MX: IN CRUISE FLIGHT FA PANEL MESSAGE: ALL LAV SMOKE DETECTORS INOP. RESET SDF1 AND SDF2 DID NOT WORK. RESET CIDS 1 PER MOC AND MESSAGE CLEARED. NOTED BY MAINTENANCE. PERFORMED SYSTEM TEST PER AMM 26-10-00. CHECKS OKAY. INDIVIDUAL TEST OF LAVATORY SMOKE ALARMS ALL PASS (REF AMM 26-17-00). OK TO CONTINUE.