As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS-ECAM HYD G ENG 1 PUMP LO PR TURNED OFF ENG 1 PUMP AS INSTRUCTED BY ECAM. PERFORMED TSM 29-11-00-810-804-A, FOUND PRESSURE SWITCH LOOSE. REMOVED AND REPLACED ENG 1 PUMP PRESSURE SWITCH (1047GK) PER AMM 29-11-17. OPS CHECK AND LEAK CHECK GOOD, NO FAULT NOTED. OK FOR SVC.