Service difficulty report · Control Valve · Airbus A330243

Difficulty date
September 27, 2024
Submitted
October 1, 2024
Operation
Air carrier
Aircraft
N391HA
Make and model
Airbus A330243
Aircraft serial
1399
Aircraft time
46,657 hours, 7,397 cycles
Part
Control Valve
Condition
Faulted
Location
Nr 2 A/C Pack
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ATB - ECAM AIR ENG 2 BLEED FAULT NOTED. ENG 2 BLEED SW PER ECAM PROCEDURE. REMOVED & REPLACED ENG 2 PRV PER AMM 36-11-52. OPS CHECK/LEAK CHECK OK. REMOVED & REPLACED PACK 2 FLOW CONTROL VALVE PER AMM 21-51-51. OPS CHECK/LEAK CHECK OK. OK FOR SVC.