As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS - GREEN HYD LOW QUANT. ECAM ON FINAL AFTER SELECTING FLAPS 2, PRESSURE NORMAL. PER CREW CONFIRMED GREEN HYD PUMPS TURN OFF BEFORE SYSTEM GOT EMPTY AND WAS STILL PRODUCING PRESSURE. FOUND LEAK AT 5105JM MANIFOLD HYD LINE. REMOVED AND REPLACED PACKING PER AMM 29-11-53. LEAK CHECK GOOD. SEVICED HYD PER AMM 12-12-29. RESET 5JR. OK FOR SVC.