As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS - DURING FLT AT 10,000 ECAM AIR ENG 2 BLEED HI TEMP. BMC BITE TEST NO FAULTS NOTED. VISUALLY INSPECTED FAV AND HP VALVE FOR LEAK. NO LEAKS NOTED. FOR PRECATIONARY REMOVED AND REPLACED FAV CONTROL THRMOSTAT FILTER PER AMM 36-11-43. LEAK CHECK GOOD. OK FOR SVC.