What was found
ETOPS - AFTER TAKEOFF WHEN SELECTING FLAPS UP THE YELLOW HYD ELETRIC PUMP BEGAN RUNNING-GUARDED SWITCH ON LIGHT ILLUMINATED, GREEN HYD ELEC PUMP ECAM MEMO,AND ELEC PUMP RUNNING INDICATION ON SD PAGE. REMOVED AND REPLACED YELLOW HYDRAULIC RELAY (24KS2) PER ESPM 20-46-50-01. SECUIRTY CHECK GOOD. PERFORMED OPS TEST OF AUTOMATIC START OF YELLOW ELECTRICAL PUMPS PER AMM 29-20-00-710-801-A. OPS TEST GOOD. OK FOR SERVICE.