As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS - ENG 2 MINOR FAULT. PERFORMED TSM 73-21-809-810-817-A. REMOVED AND REINSTALLED DATA ENTERY PLUS PER AMM 73-21-12. INSPECTED PINS PER 70-50-02-910-802-A .NO DEFECT NOTED. PERFORMED ENG RUN PER AMM 72-00-00-860-816-A.NO DEFECTS NOTED NO FAULTS ON MOTORING REPORT FADEC #2 BITE TEST GOOD .OK FOR SVC.