What was found
DIV - AIR ENG 2 BLEED FAULT DURING CLIMB. ACCOMPLISHED GVI OF #2 ENG BLEED VALVES. FOUND FAV ACTUATRO ROD BROKEN. REMOVED FAV PER AMM 36-11-54. INSTALLED FAN AIR VALVE ON ENG 2 PER AMM 36-11-54. OPS/BITE/LEAK CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DIV - AIR ENG 2 BLEED FAULT DURING CLIMB. ACCOMPLISHED GVI OF #2 ENG BLEED VALVES. FOUND FAV ACTUATRO ROD BROKEN. REMOVED FAV PER AMM 36-11-54. INSTALLED FAN AIR VALVE ON ENG 2 PER AMM 36-11-54. OPS/BITE/LEAK CHECK GOOD.